I. What is CEMS?
CEMS (Continuous Emission Monitoring System) continuously samples, analyzes, records and transmits flue gas from fixed sources, reflecting in real time the emission levels of SO?, NO?, particulates, flue gas parameters (flow, temperature, pressure, humidity, O?) and greenhouse gases (CO?, CH?, N?O). It is the core tool for environmental regulation and enterprise self-monitoring.
II. System composition
- Sampling & pretreatment:Extractive CEMS uses a probe, heated line, condensation dewatering and fine filtration to keep sample gas clean, dry and undistorted
- Gas analyzer:Multi-component analyzers using IR (GFC/NDIR), UV (DOAS) — the "heart" of the system
- Flue gas parameters:Velocity/temp/pressure/flow unit and humidity meter for concentration and emission-rate conversion
- Data acquisition & transmission (DAS):Uploads to the environmental platform via HJ212; supports calibration logs, anomaly flags and data backfill
III. Core standards overview
China has built a fairly complete fixed-source online monitoring standard system; common standard documents are downloadable from the Yantel technical center:
- HJ75-2017 Technical specification for flue gas CEMS (SO?, NO?, particulates):Specifies CEMS composition, installation, commissioning, acceptance, operation & maintenance and QA
- HJ76-2017 Requirements and test methods for flue gas CEMS:Specifies technical performance, test conditions and methods — the basis for selection and acceptance
- HJ212-2017 Data transmission standard for online monitoring systems:Specifies protocol format for data acquisition, transmission and storage
- GB37822-2019 Emission standard for volatile organic compounds:Sets requirements for VOCs fugitive emission monitoring and control
- HJ1010-2018 and HJ1013-2018: Cover ambient-air VOCs and GHG monitoring
Download HJ75-2017 (PDF) | Download HJ76-2017 (PDF) | Download HJ212-2017 (PDF) | Download GB37822-2019 (PDF)
IV. Data quality & assurance
HJ75 sets full-lifecycle data-quality requirements:
- Acceptance test:Zero drift, span drift, response time, indication error, accuracy
- Routine maintenance:Periodically clean probes, replace filters, check heated-line temperature and condenser drainage
- Periodic calibration:Auto zero/span calibration and manual comparison; at least one annual reference-method comparison
- Data validity:Flag and backfill data during calibration/maintenance to keep valid-data rate compliant
V. From CEMS to carbon emission monitoring
As the dual-carbon strategy advances, CO?, CH? and N?O are gradually included in continuous monitoring, forming an "ordinary pollutants + GHG" integrated trend. Multi-component analyzers based on GFC IR and DOAS UV can meet both environmental and carbon monitoring on one platform, lowering duplicate construction cost.