I. Why is GFC needed?
The basic principle of IR gas analysis is the Lambert–Beer law: gas molecules absorb energy at characteristic IR bands, and absorption intensity is proportional to concentration. However, real industrial flue gas has complex components; common species like H?O and CO? cause severe spectral interference over broad bands, so a single narrow-band filter cannot yield stable, accurate results.
GFC was born to solve this: it uses a cell filled with the target gas as a "correlation filter". By alternately measuring against a reference channel without the target gas, the influence of interfering components is largely canceled, obtaining a high-selectivity, high-stability concentration signal.
II. How GFC works
The core component of a GFC analyzer is the gas filter wheel. The wheel carries two types of channels:
- Correlation cell:Filled with high-concentration target gas (e.g., CO?); incoming IR is almost fully absorbed, measuring background and interference signals
- Measure cell:Filled with a reference gas like nitrogen that does not absorb IR; the IR passes through and is absorbed by the target gas in the sample
The IR radiation from the source passes through the two channels of the rotating wheel, then through the sample cell to the detector. The difference between the two channels directly reflects the target gas absorption in the sample, while common-mode interference (water vapor, dust, source drift) is automatically removed. This mutual-reference measurement makes GFC markedly superior to ordinary NDIR in zero stability and anti-interference capability.
III. Typical GFC measurement targets
- CO?:Core parameter for fixed-source carbon accounting; range covers 0–20% or higher, repeatability within ±1% FS
- CO:Key indicator of combustion efficiency and incomplete-combustion control
- CH?:Leak and emission monitoring for natural gas, coal mines, livestock farms; GFC with long optical path achieves ppm-level measurement
- N?O:Agricultural and chemical process emission monitoring, still needing high sensitivity at low concentration
IV. GFC combined with long optical path absorption
For low-concentration GHGs like CH? and N?O, a single short optical path cell cannot reach enough sensitivity. The YTG-1000 series combines GFC with a long-path multi-reflection cell: light shuttles through the cell many times, extending the effective path from tens of centimeters to several meters, significantly increasing the absorption signal at the same volume so ppm-level GHGs can be detected stably, while keeping fast response to meet CEMS online requirements.
V. GFC's role in carbon emission monitoring
Following China's carbon emission monitoring roadmap, fixed-source CEMS measurement of CO?, CH? and N?O recommends IR-absorption technologies. With its high selectivity, high stability and low maintenance, GFC has become an ideal choice for carbon emission monitoring and GHG inventory compilation, widely used in power, steel, cement and petrochemical industries.