Core principle: characteristic IR absorption of gas molecules

The core principle of an OGI camera is the characteristic absorption of specific IR bands by gas molecules. When the background (e.g., equipment surface, sky, ground) emits infrared radiation, the leaking gas cloud selectively absorbs energy at certain wavelengths, reducing the IR intensity passing through it. After the detector captures this difference and enhances it with algorithms, a recognizable "gas cloud" forms on screen.

For example, most volatile organic compounds (VOCs) have strong absorption peaks in the 3.2–3.5 μm mid-wave IR band; sulfur hexafluoride (SF?) is better detected in the 10.3–10.7 μm long-wave IR band. By configuring a narrow-band filter at the matching band, OGI devices greatly suppress interference from other bands, keeping only the target gas's effective information.

Why are cooled detectors needed?

Radiation signals from gas leaks are usually very weak, especially at long range or low concentration. Cooled detectors (e.g., MCT, T2SL) lower the detector temperature to significantly reduce thermal noise, so the noise-equivalent temperature difference (NETD) can reach as low as 10–20 mK, capturing the tiny absorption differences of gases.

Features of OGI

  • High sensitivity:Detects very small leaks; captures signals even at long range
  • Visualization:Shows the leak cloud in pseudo-color in real time, locating the source fast
  • Non-contact:No interruption of industrial processes, keeping personnel safe
  • Broad coverage:Methane, VOCs, SF?, NH? and more

Synergy with infrared gas analyzers

OGI leans toward qualitative localization — answering "where is the leak"; an infrared gas analyzer provides quantitative concentration — answering "how much". Together they build a complete monitoring system from leak discovery and localization to emission quantification, an ideal combination for LDAR and carbon accounting.